Post

Moxa AIG-302 ThingsPro Edge Vulnerabilities

Moxa AIG-302 ThingsPro Edge Vulnerabilities

Moxa AIG-302 ThingsPro Edge Vulnerabilities 🚨

Published on: October 20, 2026
Source: CISA

Successful exploitation of these vulnerabilities could allow an attacker to obtain and disclose sensitive information. The Moxa AIG-302 ThingsPro Edge firmware <=1.4.0 is affected by two critical vulnerabilities, CVE-2026-109812 and CVE-2026-109813. These vulnerabilities impact Critical Infrastructure Sectors including Critical Manufacturing, Energy, and Water and Wastewater Systems, with deployments reported worldwide.

Vulnerability Details:

  • CVE-2026-109812: This describes a missing authorization vulnerability (CWE-862) in the internal API /api/v1/secrets/ for some of Moxa’s industrial computing products. A privileged authenticated attacker with adjacent network access could exploit this vulnerability to access sensitive information, potentially resulting in the disclosure of confidential data, including cryptographic key material.
  • CVE-2026-109813: This covers a hard-coded cryptographic key vulnerability (CWE-321) in the /usr/bin/sysman for some of Moxa’s industrial computing products. An unauthenticated attacker with adjacent network access could exploit the exposed private key material to compromise the confidentiality and integrity of communications.

Moxa has provided a fix for the vulnerability in v1.4.1. Users are encouraged to obtain and apply the update through one of the following methods:

  • If the AIG-302 has Internet access, log in to the AIG-302 Web Console, go to Maintenance > Software Upgrades, and click Check for upgrades to check for and obtain the update.
  • Users can also download the v1.4.1 patch manually from either the official AIG-302 product website or the Moxa Software Release Service. Then, log in to the AIG-302 Web Console, navigate to Maintenance > Software Upgrades, and select Package Upload to upload the patch.

For more information, refer to Moxa’s security advisory MPSA-262560. CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, including:

  • Minimizing network exposure for all control system devices and/or systems.
  • Ensuring they are not accessible from the internet.
  • Locating control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs).

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.