2025-10-01 Daily Vulns
NEW:
CVE | vendor-product | description | metric | Referenceurl | title | GithubURL | |
---|---|---|---|---|---|---|---|
CVE-2025-10773 | B-Link - BL-AC2100 | A security flaw has been discovered in B-Link BL-AC2100 up to 1.0.3. Affected by this issue is the function delshrpath of the file /goform/set_delshrpath_cfg of the component Web Management Interface. The manipulation of the argument Type results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.Es wurde eine Schwachstelle in B-Link BL-AC2100 bis 1.0.3 entdeckt. Dabei geht es um die Funktion delshrpath der Datei /goform/set_delshrpath_cfg der Komponente Web Management Interface. Durch das Manipulieren des Arguments Type mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff lässt sich über das Netzwerk starten. Die Ausnutzung wurde veröffentlicht und kann verwendet werden. | CVSS4.0: 8.7 - HIGH CVSS3.1: 8.8 - HIGH | 0 1 2 3 | Exploitation: pocAutomatable: noTechnical Impact: total | B-Link BL-AC2100 Web Management set_delshrpath_cfg delshrpath stack-based overflow | github |
CVE-2020-11909 | n/a - n/a | The Treck TCP/IP stack before 6.0.1.66 has an IPv4 Integer Underflow. | CNA n/a CVSS3.1: 9.1 - CRITICAL | 0 1 2 3 4 5 6 7 8 | Exploitation: noneAutomatable: yesTechnical Impact: total | undefined | github |
CVE-2019-6833 | Schneider Electric SE - Magelis HMI Panels | A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel. | CNA n/a CVSS3.1: 6.5 - MEDIUM | 0 1 | Exploitation: noneAutomatable: noTechnical Impact: partial | undefined | github |
CVE-2025-2394 | Ecovacs - Ecovacs Mobile and Android Application | Ecovacs Home Android and iOS Mobile Applications up to version 3.3.0 contained embedded access keys and secrets for Alibaba Object Storage Service (OSS), leading to sensitive data disclosure. | CVSS4.0: 4.7 - MEDIUM | 0 1 | Exploitation: noneAutomatable: noTechnical Impact: partial | Disclosure of Alibaba (OSS) Keys In Ecovacs Home Android and iOS Mobile Applications | github |
This post is licensed under CC BY 4.0 by the author.